Page 2
Table of Contents
1 General
1.1 Scope
2 Input Characteristics
2.1 Input Voltage
2.2 Input Frequency
2.3 Max. Input AC Current
2.4 Inrush Current
2.5 Efficiency
3 Output characteristics
3.1 Nominal Operation Output
3.2 Remote On/Off controlled mode
3.3 Regulation
3.4 Rise Time
3.5 Hold-up Time
3.6 5 VSB
3.7 PG-OK
3.8 3.3V Sense
3.9 Capacitive Load
4 Protection
4.1 Input Protection
4.2 Output Protection
5 Start Stability
5.1 No Load Start
5.2 Cold Start
6 Environments
6.1 Temperature and Humidity
6.2 Altitude
6.3 Vibration and Shock
7 Conducted EMI
Zobrazit stránku 0
1 2 3 4 5 6 ... 12 13

Shrnutí obsahu

Strany 1 - Table of Contents

Page 2Table of Contents 1 General1.1 Scope 2 Input Characteristics 2.1 Input Voltage 2.2 Input Frequency 2.3 Max. Input AC Current 2.4 Inrush C

Strany 2

Page 1115.3 Pin Designation :15.3.1 DC CONNECTOR REQUIREMENTSList or recognized component appliance wiring material(AVLV2),CN,ratedmin 850C ,300VAC sh

Strany 3 - 2. Input Characteristics

Page 1215.3.4 +12V Power Connector PB1Connector : Molex 39-01-2040 or quivalentPin Signal 18 AWG Wire1 COM Black2 COM Black3 COM Black4 COM Black5 +1

Strany 4 - 3. Output characteristics

Page 1315.3.6 Case FAN control Connector P3 (FAN speed signal) Connector : AMP 1-480424-0 orMOLEX 8981-04P or approved equivalent Pin Signal 22 AWG W

Strany 5 - 3.6 5VSB

Page 14850WCross Regulation (5V rail+ 3.3V rail vs. 12V rail)0204060801001201401601802002200 100 200 300 400 500 600 700 800 90012V Power (Watts)5V +

Strany 6 - 6. Environments

Page 38 Product Safety8.1 Safety Requirement8.2 Leakage Current 8.3 Insulation Resistance 8.4 Dielectric Voltage Withstand9 Power Good Signal 1

Strany 7 - 9. Power Good Signal

Page 41. General1.1 ScopeThis specification defines the performance characteristics of a single phase 850 watts, 8 output power supply : +5V, +12V1, +

Strany 8 - 10. FanM signal

Page 53. Output characteristics 3.1 Normal Operation OutputOutputVoltageLoadMINRangeMAXRegulationRipple P-P Max.Ripple & Noise P-P Max. 1. +5V 0.5

Strany 9 - 15. Mechanical Specification

Page 63.5 Hold-up TimeDC +5V output maintains at least 16mS after power off which hold within para 3.1under 115V/63Hz and 230V/47Hz condition. 3.6 5

Strany 10 - 15.3 Pin Designation :

Page 74. Protection4.1 Input ProtectionIn primary circuit of the power supply , a protected fuse is inserted. Only internal fault of the power supply

Strany 11

Page 86.2 AltitudeThe power supply can operate normally at any altitude between 0 to 10000 feet. 6.3 Vibration and Shock6.3.1 Sweep and resonance sear

Strany 12

Page 9Time Diagram Figure 1* T1 : Turn on time ( 2 sec. Max.) * T2 : Rise time ( ? 20mS Max.) * T3 : Power good turn on delay time ( 100 < T3 <

Strany 13 - (5V rail +3.3V rail)

Page 10 Figure 3 11. MTBFThe MTBF of the power should be 100,000 hours min.12. Burn-In 12.1 Input VoltageApplying 220Vac for 230V model.12.2 Test Co